    DEAN Steel Buildings, inc.  provides a wide range of flashing for any purpose you may have.  In the case that the following table does not meet the flashing criteria you need, please do not hesitate to contact your Estimator or Salesperson and ask about our CUSTOM FLASHING ( a sketch will have to be provided).

    Please refer to the following when asked for slope Code:

    * Miter or Slope Code

    A 0:12 J 4:12
    B 0.5:12 K 4.5:12
    C 1:12 L 5:12
    D 1.5:12 M 5.5:12
    E 2:12 N 6:12
    F 2.5:12 X SPECIAL

    Part No. Size
    Length
    Description Weight

    Peak Finial
    FNN6C010500 Pitch = 1:12 (GLM/COL) 1.7
    FNN6J010500 Pitch = 4:12 (GLM/COL) 1.7
    FNO6C010500 Pitch = 1:12 (GLM/COL) 1.7
    FNO6J010500 Pitch = 4:12 (GLM/COL) 1.7

    Parapet Inside Corner Box
    FL4397 (GLM/COL) 1.5

    Sculptured Rake End
    FL4398 Right handed
    (GLM/COL)
    1.5
    FL4399 Left handed
    (GLM/COL)
    1.5

    Sculptured Gutter
    GU120BA4 24 ga. 20’7″ Basic 47.0
    GU120EX4 24 ga. 20’7″ Extension 45.0
    GU120BA6 26 ga. 20’7″ Basic 36.0
    GU120EX6 26 ga. 20’7″ Extension 34.0

    Assembly includes brackets and rivets.  Basic assembly also includes two gutter ends and gutter seal.  Third digit is roof pitch, last digit is gauge.

    GUA4-200700 24 ga. 20’7″ Gutter only 40.0
    GUA6-200700 24 ga. 30.0

    4″x5″ Downspout
    DSA6-040100 26 ga. DSA = StraightDSB = With elbowStraps and mounting hardware to be added separately. 5.9
    DSB6-040100 26 ga. 5.9
    DSA6-060100 26 ga. 8.8
    DSB6-060100 26 ga. 8.8
    DSA6-100200 26 ga. 14.7
    DSB6-100200 26 ga. 14.7
    DSA6-120100 26 ga. 17.6
    DSB6-120100 26 ga. 17.6

    4″x5″ downspout Elbow
    FL4110 26 ga. 45° elbow 1.3
    FL4104 26 ga. 95° elbow 1.3
    FL4105 26 ga. 95° elbow 1.3
    FL4107 26 ga. 90° elbow 1.3

    8″ offset for 4″x5″ Downspout
    FL4108 26 ga. 8″ offset 2.7

    Scupper 4″x5″
    FL4109 26 ga. Scupper 0.25
    FL4106 26 ga. Downspout strap 1″x18″ 0.11

    Standard Gutter Bracket
    HW5635 – 1:12
    HW5636 – 4:12
    Top Gutter bracket comes in two pieces. Must be field assembled.  Order fastener separately. 0.6
    HW9201 Bottom

    Proseam Gutter Bracket
    HW5647 – 1:12
    HW5648 – 4:12
    Top Gutter bracket comes in two pieces. Must be field assembled.  Order fastener separately. 0.6
    HW9201 Bottom

    Valley Gutter (Eave to Eave) 14 ga.
    VGR4C100000 1:12 to 1:12 Valley Gutter
    GNZ
    87.5
    VGR4J100000 4:12  to 4:12 Valley Gutter
    GNZ
    87.5

    Please refer to Slope code at the beginning of this page (5th digit)

    AN1255 14 ga. Splice band – GNZ 2.2
    AN1256 14 ga. End Cap – GNZ 2.3

    Valley Gutter (wall to Eave) 14 ga.
    VGW4C100000 Wall to 1:12 valley gutter
    GNZ
    101.0

    Please refer to Slope code at the beginning of this page (5th digit)

    AN1251 14 ga. Splice band – GNZ 3.0
    AN1252 14 ga. End Cap – GNZ 2.5

    Parapet Gutter
    GUP6-100200 26 ga. Parapet gutter – (GLM/COL) 22.4
    GUP4-100200 24 ga. Parapet gutter – (GLM/COL) 30.2

    Please refer to Slope code at the beginning of this page (5th digit)


    Inside Corner Flashing (RS)
    ISC6-040100 26 ga.  (GLM/COL) 5.0
    ISC6-060100 26 ga. (GLM/COL) 7.4
    ISC6-100200 26 ga. (GLM/COL) 12.3

    Inside Corner Flashing (RT)
    ICT6-040100 26 ga. (GLM/COL) 3.9
    ICT6-060100 26 ga. (GLM/COL) 5.9
    ICT6-100200 26 ga. (GLM/COL) 9.8

    Inside Corner Flashing opt. 3″
    ICO6-040100 26 ga. (GLM/COL) 2.0
    ICO6-060100 26 ga. (GLM/COL) 3.0
    ICO6-100200 26 ga. (GLM/COL) 5.0

    Inside Corner Flashing Univ. 6″
    ICU6-040100 26 ga. (GLM/COL) 4.0
    ICU6-060100 26 ga. (GLM/COL) 5.9
    ICU6-100200 26 ga. (GLM/COL) 9.7

    Outside Corner Flashing (RS)
    OCS6-040100 26 ga. (GLM/COL) 3.0
    OCS6-060100 26 ga. (GLM/COL) 4.5
    OCS6-100200 26 ga. (GLM/COL) 7.4
    OCS6-120100 26 ga. (GLM/COL) 7.8

    Outside Corner Flashing (RT)
    OCT6-040100 26 ga. (GLM/COL) 4.9
    OCT6-060100 26 ga. (GLM/COL) 7.3
    OCT6-100200 26 ga. (GLM/COL) 12.2
    OCT6-120100 26 ga. (GLM/COL) 14.5

    Outside Corner Flashing Univ. 6″
    OCU6-040100 26 ga. (GLM/COL) 3.2
    OCU6-060100 26 ga. (GLM/COL) 4.9
    OCU6-100200 26 ga. (GLM/COL) 8.3

    Standard Eave Flashing
    FEA6C100200 26 ga. (GLM/COL) 4.7
    FEA6J100200 26 ga. (GLM/COL) 4.7

    High Side Sculptured Eave Flashing
    FEH6C100200 26 ga. (GLM/COL) 14.7
    FEH4C100200 24 ga. (GLM/COL) 20.0

    Low Side Sculptured Eave Flashing
    FEL6C100200 26 ga. (GLM/COL) 14.7

    Proseam Eave Flashing
    FEP6C100200 26 ga. (GLM/COL) 4.9

    Reverse slope Eave Flashing
    FER6C100200 26 ga. (GLM/COL) 7.4

    Eave flashing Optional
    FEO6C100200 26 ga. (GLM/COL)Please refer to Slope code at the beginning of this page (5th digit) 4.9

    Vertical Fascia Cap Flashing
    FAO6-040100 26 ga. (GLM/COL) 4.9
    FAO6-060100 7.3
    FAO6-100200 12.2
    FAV6-040100 4.9
    FAV6-060100 7.3
    FAV6-100200 12.2

    Sloped Fascia cap flashing
    FAX6-040100 26 ga. (GLM/COL) 4.9
    FAX6-060100 7.3
    FAX6-120100 12.2

    Sloped Fascia Base
    FBS6-040100 26 ga. (GLM/COL) 3.0
    FBS6-060100 4.4
    FBS6-100200 7.4

    Vertical Fascia Base Flashing
    FBV6-040100 26 ga. (GLM/COL) 3.0
    FBV6-060100 4.4
    FBV6-100200 7.4

    Fascia End Flashing
    FAE6-040100 26 ga. (GLM/COL) 3.0
    FAE6-060100 4.4
    FAE6-100200 7.4

    Jamb Flashing (RS)
    FJS6-070200 26 ga. (GLM/COL) 2.6
    FJS6-080200 3.0
    FJS6-100200 3.7

    Jamb Flashing (RT)
    FJT6-070200 26 ga. (GLM/COL) 2.6
    FJT6-080200 3.0
    FJT6-100200 3.7

    Header Flashing (RS)
    FHS6-030410 26 ga. (GLM/COL) 1.2
    FHS6-040410 1.6
    FHS6-060410 2.3
    FHS6-080200 3.0
    FHS6-100200 3.7

    Header Flashing (RT)
    FHT6-030410 26 ga. (GLM/COL) 1.2
    FHT6-040410 1.6
    FHT6-060410 2.3
    FHT6-080200 3.0
    FHT6-100200 3.7

    Shadow Panel Hem Flashing
    FHE6-100200 26 ga. (GLM/COL) 2.5

    Jamb or Header Cap Flashing
    FJC6-040100 26 ga. (GLM/COL) 3.9
    FJC6-060100 5.9
    FJC6-100200 9.8

    Panel Cap Flashing (RS)
    FCS6-100200 26 ga. (GLM/COL) 2.5

    Panel Cap Flashing (RT)
    FCT6-100200 26 ga. (GLM/COL) 2.5

    Window Header Flashing (RT)
    FWH6-100200 26 ga. (GLM/COL) 4.9

    Window Sill Flashing – Univ.
    FWS6-100200 26 ga. (GLM/COL) 3.7

    Partition Flashing
    FPF6-060100 26 ga. (GLM/COL)Between girt and purlins at partition. 5.9
    FPF6-100200 9.8

    Transition Flashing (RT – RS)
    FTT6-100200 26 ga. (GLM/COL) 12.3
    FTS6-100200 12.1

    Rake Flashing (RT – RS)
    FRA6-200700 26 ga. (GLM/COL) 29.7
    FRA4-200700 24 ga. 36.8

    Rake Flashing – Proseam
    FRP6-100200 26 ga. (GLM/COL) 14.8
    FRP4-100200 24 ga. 19.9

    Rake Slide
    FRS6-100200 26 ga. (GLM/COL) 3.7


    Rof to Roof Flashing

    FRR6-100200 26 ga. (GLM/COL)Please refer to Slope code at the beginning of this page (5th digit) 9.8


    Eall to Roof Flashing

    FWR6-100200 26 ga. (GLM/COL) 9.8

    Wing Unit Roof Flashing
    FWU6-100200 26 ga. (GLM/COL)Please refer to Slope code at the beginning of this page (5th digit) 7.4

    Gravel Stop for Flat Roofs
    FL4033 26 ga. (GLM/COL) 7.3

    Masonry Eave Flashing
    FEM6-100200 26 ga. (GLM/COL)Please refer to Slope code at the beginning of this page (5th digit) 12.2

    Masonry Rake Flashing
    FRM6-100200 26 ga. (GLM/COL) 4.9

    Skylight Trim – Univ
    FSK6-110100 26 ga. (GLM/COL) 2.7

    Canopy Soffit Flashing
    FSS6-100200 26 ga. (GLM/COL)Please refer to Slope code at the beginning of this page (5th digit) 2.5
    FST6-100200 2.5

    Canopy Eave Flashing
    FCE6-040100 26 ga. (GLM/COL) 3.0
    FCE6-060100 4.4
    FCE6-100200 7.4

    Roof Extension Rake Flashing
    FRE6-100200 26 ga. (GLM/COL) 3.7

    Roof Extension Soffit Flashing
    FRF6-100200 26 ga. (GLM/COL) 3.7

    Slide Door Hood Flashing
    FSH6-100200 26 ga. (GLM/COL) 14.7

    Slide Door Bypass Flashing
    FSB6-100200 26 ga. (GLM/COL) 3.7

    Facebook

    What’s New?

    • Flashing
    • Dean Steel Buildings & AC-472
    • Miami-Dade County Product Approval
    • Surplus Equipment
    • Panels
    • Paint Finish & Color Selections
    • Color & Gauge Availability by Panel
    • Solar Reflectivity (R) & Solar Reflectance Index (SRI) by Color
    • Home
    • Surplus Inventory
    • Panel Warranties
    • Careers - Thomasville
    • Careers - Fort Myers
    • 2015.05.24 Color & Gauge Availability by Panel
    • 2015.05.24 Paint Finish & Color Selections
    • DSBT Decision Tree
    • 2018.07.16 Dean Steel Buildings & ISO 9001

    Contact Us

    Fort Myers

    General Offices, Sales & Mfg. Plant

    2929 Industrial Ave Fort Myers, Florida 33901
    (239) 334-1051 Fax (239) 334-2432

    Cedartown

    Sales & Manufacturing Plant

    500 Tenth Street Cedartown, Georgia 30125
    (770) 748-7900 Fax (770) 748-5300

    Thomasville

    Sales & Manufacturing Plant

    71 Airport Rd. Thomasville, Georgia 31757
    (229) 225-1112 Fax (229) 225-1175

    webmail@deansteelbuildings.com

    Contact Form
    Copyright © 2011-2024 Dean Steel Buildings, Inc. All Rights Reserved.
    Top